Transformator markalari ensiklopediyasi

Markani o'qish: fazalar, sovutish, o'ramlar, rostlash, quvvat va kuchlanish.

Marka dekoderi

ТДТН-25000/110-У1

  • ТFazalar soniuch fazali
  • ДSovutishmoyli, radiatorlarni ventilyatorlar puflaydi (moy tabiiy aylanadi)
  • ТO'ramlar soniuch o'ramli
  • НKuchlanishni rostlashkuchlanish yuklama ostida rostlanadi (RPN)
Nominal quvvat
25000 kVA = 25 MVA
YK kuchlanish sinfi
110 kV
Iqlim bajarilishi
mo'tadil iqlim, ochiq havoda

Viktorina

Modellar

MarkaS, MVAKuchlanish, kVUlanish guruhiuk, %P0, kVtPk, kVtRostlash
25115 / 38,5 / 11Yn/Yn/Δ-0-1110,5 / 17,5 / 6,528,5140RPN
25115 / 10,5Yn/Δ-Δ-11-1110,525120RPN
16115 / 11Yn/Δ-1110,51885RPN
10115 / 11Yn/Δ-1110,51458RPN
6,335 / 11Y/Δ-117,5846,5RPN
435 / 11Y/Δ-117,55,633,5RPN
2,535 / 11Y/Δ-116,54,123,5RPN
1,610 / 0,4Δ/Yn-1162,6516,5PBV
110 / 0,4Δ/Yn-115,51,610,8PBV
0,6310 / 0,4Δ/Yn-115,51,057,6PBV

⚠ Pasport qiymatlari — kataloglardagi tipik qiymatlar; aniq transformator pasporti bo'yicha tekshirilsin (TEKSHIRUV ro'yxati, 2-bo'lim).

Harflar jadvali

KirillLotinGuruhMa'nosi
АATuriavtotransformator (o'ramlar elektr jihatdan bog'langan)
ОOFazalar sonibir fazali
ТTFazalar soniuch fazali
РRO'ram bajarilishipast kuchlanish o'rami ikki parchali (ikkiga bo'lingan)
ДЦDTsSovutishmoyli, majburiy havo puflash va moyning majburiy aylanishi (nasos)
МЦMTsSovutishmoyli, tabiiy havo va moyning majburiy aylanishi
ЦTsSovutishmoy-suv sovutish, moyning majburiy aylanishi
ДDSovutishmoyli, radiatorlarni ventilyatorlar puflaydi (moy tabiiy aylanadi)
МMSovutishmoyli, tabiiy sovutish (moy va havo tabiiy aylanadi)
СSSovutishquruq (havo bilan tabiiy sovutish)
ЗZMoy himoyasimoy himoyalangan (azot yostig'i bilan, kengaytirgichsiz)
ГGMoy himoyasigermetik bajarilgan (kengaytirgichsiz, bak to'liq moy bilan to'ldirilgan)
ТTO'ramlar soniuch o'ramli
НNKuchlanishni rostlashkuchlanish yuklama ostida rostlanadi (RPN)